Fluke 789 FC ProcessMeter™ and Temperature Kit 100% New & Original with very competitive price and One year Warranty
- Product description
- Contact us
Fluke 789 FC ProcessMeter™ and Temperature Kit
100% New & Original with very competitive price and One year Warranty
Key features
Fluke 789 Temperature Kit features:
* Unique new wireless measurement logging capability
* Temperature measurement from -200 °C to 1372 °C using the t3000 FC
* 24 V Loop power supply
* HART mode setting with loop power (adds 250 ohm resistor)
* 100% larger dual display
* 1200 ohm drive capability on mA source
* Enhanced backlight with two brightness settings
* 0% to 100% mA Span Check buttons to toggle between 4 and 20 mA
* Infrared I/O serial port compatible with
* FlukeView® Forms Software Version 2.1
* Externally accessible fuses for easy replacement
Product overview: Fluke 789 FC ProcessMeter™ and Temperature Kit
The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals,
combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement
module and the wireless data logging capabilities of Fluke Connect® with ShareLive™ video call,
process technicians can now do a lot more while carrying a lot less.
And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.
Specifications: Fluke 789 FC ProcessMeter™ and Temperature Kit
Fluke 789 ProcessMeter™ with Fluke Connect™
| Specifications | ||
| Current measurement | Range | 0-1 A AC or DC |
| Resolution | 1 mA | |
| Accuracy | 0.2% + 2 LSD (DC) | |
| Range | 0-30 mA | |
| Resolution | 0.001 mA | |
| Accuracy | 0.05% + 2 lSD | |
| Current sourcing | Range | 0-20 mA or 4-20 mA |
| Resolution | 0.05% of span | |
| Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
| Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
| Continuity | Beeps for resistance < 100 Ω | |
| Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
| Resolution | 0.1 mV to 1.0 V | |
| Accuracy | 0.1% Rdg + 1 LSD (V DC) | |
| Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
| Diode test | 2.0 V shoes diode voltage drop | |
| Display current and % of span | Yes | |
| Auto Step, Auto Ramp | Yes | |
| Environmental Specifications | ||
| Operating temperature | -20°C to 55°C | |
| Storage temperature | -40°C to 60°C | |
| Humidity (without condensation) | 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C | |
| Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) | |
| Safety Specifications | ||
| Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
| Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V | |
| Maximum voltage | 1000 V RMS | |
| Mechanical and General Specifications | ||
| Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
| Weight | 610 g (1.6 lbs) | |
| Batteries | 4 AA alkaline batteries | |
| Warranty | 3 years | |
| Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
| Shock and vibration | Random, 2 g, 5-500 Hz 1 meter drop test | |
Fluke t3000 FC Wireless K-Type Temperature Module
| General Specifications | ||||
| Range K-Type | -200°C to 1372°C | |||
| Resolution | 0.1°C | |||
| Accuracy | ±[0.5% + 0.5°C] counts | |||
| Input terminals | K-type mini | |||
| LCD w/backlight | 3 ½ digits | |||
| Log rate/interval | 1 sec minimum/adjustable by PC | |||
| Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
| Battery life | 400 hours | |||
| Memory | Record up to 65,000 readings | |||
| RF communications | 2.4 GHZ ISM Band | |||
| RF communication range | Open air, unobstructed | Up to 20 m | ||
| Obstructed, sheetrock wall | Up to 6.5 m | |||
| Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
| Operating temperature | -10°C to +50°C | |||
| Storage temperature | -40°C to +60°C | |||
| Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
| Temperature scale | ITS-90 | |||
| Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
| Altitude | Operating | 2,000 m | ||
| Storage | 12,000 m | |||
| EMC | EN 61326-1:2006 | |||
| Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
| Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
| Ingress Protection (IP) rating | IP42 | |||
| Pollution Degree | 2 | |||
| Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
| Weight | .22 kg (8 oz) | |||
| Not compatible with Fluke CNX test tools | ||||
| Specifications | ||
| Current measurement | Range | 0-1 A AC or DC |
| Resolution | 1 mA | |
| Accuracy | 0.2% + 2 LSD (DC) | |
| Range | 0-30 mA | |
| Resolution | 0.001 mA | |
| Accuracy | 0.05% + 2 lSD | |
| Current sourcing | Range | 0-20 mA or 4-20 mA |
| Resolution | 0.05% of span | |
| Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
| Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
| Continuity | Beeps for resistance < 100 Ω | |
| Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
| Resolution | 0.1 mV to 1.0 V | |
| Accuracy | 0.1% Rdg + 1 LSD (V DC) | |
| Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
| Diode test | 2.0 V shoes diode voltage drop | |
| Display current and % of span | Yes | |
| Auto Step, Auto Ramp | Yes | |
| Environmental Specifications | ||
| Operating temperature | -20°C to 55°C | |
| Storage temperature | -40°C to 60°C | |
| Humidity (without condensation) | 95% up to 30°C 75% up to 40°C 45% up to 50°C 35% up to 55°C | |
| Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C) | |
| Safety Specifications | ||
| Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
| Overvoltage category | IEC 1010-1 CAT III 1000 V IEC 1010-1 CAT IV 600 V | |
| Maximum voltage | 1000 V RMS | |
| Mechanical and General Specifications | ||
| Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
| Weight | 610 g (1.6 lbs) | |
| Batteries | 4 AA alkaline batteries | |
| Warranty | 3 years | |
| Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
| Shock and vibration | Random, 2 g, 5-500 Hz 1 meter drop test | |
Fluke t3000 FC Wireless K-Type Temperature Module
| General Specifications | ||||
| Range K-Type | -200°C to 1372°C | |||
| Resolution | 0.1°C | |||
| Accuracy | ±[0.5% + 0.5°C] counts | |||
| Input terminals | K-type mini | |||
| LCD w/backlight | 3 ½ digits | |||
| Log rate/interval | 1 sec minimum/adjustable by PC | |||
| Battery type | 2 AA, NEDA 15 A, IEC LR6 | |||
| Battery life | 400 hours | |||
| Memory | Record up to 65,000 readings | |||
| RF communications | 2.4 GHZ ISM Band | |||
| RF communication range | Open air, unobstructed | Up to 20 m | ||
| Obstructed, sheetrock wall | Up to 6.5 m | |||
| Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |||
| Operating temperature | -10°C to +50°C | |||
| Storage temperature | -40°C to +60°C | |||
| Temperature coefficient | 0.01% of reading +0.03°C per °C | |||
| Temperature scale | ITS-90 | |||
| Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C | |||
| Altitude | Operating | 2,000 m | ||
| Storage | 12,000 m | |||
| EMC | EN 61326-1:2006 | |||
| Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 | |||
| Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE | |||
| Ingress Protection (IP) rating | IP42 | |||
| Pollution Degree | 2 | |||
| Size (H x W x D) | 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) | |||
| Weight | .22 kg (8 oz) | |||
| Not compatible with Fluke CNX test tools | ||||
