Products

Schneider LTMR08DBD Motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet New & Original with very competitive price and One year Warranty

New & Original
LTMR08DBD
Schneider LTMR08DBD Motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet New & Original with very competitive price and One year Warranty
Please contact us for more information.

Schneider LTMR08DBD Motor controller LTMR TeSys T - 24 V DC 8 A for DeviceNet 

New & Original with very competitive price and One year Warranty 





TeSys T is a smart motor management system. When associated with a short circuit protection device 

and a contactor, the device provides full motor monitoring, control and protection for electrical motors.




Main
range
TeSys

product name
TeSys T

device short name
LTMR

product or component type
Motor controller

device application
Equipment monitoring and control

measurement current
0.4…8 A

[Us] rated supply voltage
24 V DC

current consumption
56...127 mA

supply voltage limits
20.4…26.24 V DC

communication port protocol
DeviceNet

bus type
DeviceNet ISO 1198 interface, addressing 1...64, transmission rate 125...500 kbit/s, terminal block with 4 twisted shielded pairs cable

Complementary
[Ui] rated insulation voltage
690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508

[Uimp] rated impulse withstand voltage
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1

short-circuit withstand
100 kA conforming to EN/IEC 60947-4-1

associated fuse rating
4 A gG for output
0.5 A gG for control circuit

protection type
Thermal overload protection
Overload
Power factor variation
Reverse polarity protection
Earth-leakage protection
Thermal protection
Overload (long time)
Phase failure
Load fluctuation
Phase unbalance
Locked rotor

network and machine diagnosis type
Fault recording
Waiting time after overload tripping
Remaining operating time before overload tripping
Phase fault and earth fault trip counters
Starting current and time
Trip history information
Trip context information
Motor control command recording
Running hours counter/operating time
Event recording

logic input number
6

input current
7 mA

current state 0 guaranteed
Logic input: < 5 V and <= 15 mA for 5 ms

current state 1 guaranteed
Logic input: < 15 V and 2...15 mA for 15 ms

maximum output switching frequency
2 Hz

load current
5 A at 250 V AC for logic output
5 A at 30 V DC for logic output

permissible power
480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)

maximum operating rate
1800 cyc/h

contacts type and composition
1 NO + 1 NC fault signal
3 NO

metering type
Phase current I1, I2, I3 RMS
Temperature
Earth-fault current
Average current Iavg
Imbalance current

measurement accuracy
5...15 % earth fault current internal measurement (for current > 0.1 A)
1 % voltage (100...830 V)
3 % power factor (cos φ > 0.6)
5 % earth fault current external measurement (< 5 % or 0.01 A)
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power

overvoltage category
III

connection pitch
5.08 mm

connections - terminals
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end

tightening torque
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm

pollution degree
3

electromagnetic compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5

width
91 mm

height
61 mm

depth
122.5 mm

net weight
0.53 kg

web services
Web server

compatibility code
LTMR


LTMR08DBD_副本

Copyright © 2019 Sunup (Wuhan) Industrial Equipment Co., Ltd. All Right Reserved.


Sunup (Wuhan) Industrial Equipment Co., Ltd is not an authorized reseller, agent or affiliate of any brand or manufacturer. All trademarks, brand names and logos whose products are sold on the website are used for identification purposes only and are registered trademarks of their respective owners, all rights reserved. The use of a trademark, brand name or product on our website does not imply that the company trademark or brand belongs to or endorses our website. All products are 100% original, genuine and legally purchased from authorized sources.