Phoenix Single relay - REL-MR- 24DC/21 - 2961105 New & Original with very competitive price and One year Warranty
- Product description
- Contact us
Phoenix Single relay - REL-MR- 24DC/21 - 2961105
Plug-in miniature power relay, with power contact, 1 PDT, input voltage 24 V DC
Key Commercial Data
| Orderkey | 2961105 |
|---|---|
| Packing unit | 1 pc |
| Minimum order quantity | 10 pc |
| Catalog page | Page 284 (C-5-2019) |
| GTIN | 4017918130893 |
| Weight per Piece (excluding packing) | 6.000 g |
| Custom tariff number | 85364190 |
| Country of origin | CZ (Czech Republic) |
Dimensions
| Width | 5 mm |
|---|---|
| Height | 28 mm |
| Depth | 15 mm |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 85 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | RT III |
Coil side
| Nominal input voltage UN | 24 V DC |
|---|---|
| Input voltage range in reference to UN | see diagram |
| Typical input current at UN | 7 mA |
| Typical response time | 5 ms |
| Typical release time | 2.5 ms |
| Coil resistance | 3390 Ω ±10 % (at 20 °C) |
| Power dissipation for nominal condition | 0.17 W |
Contact side
| Contact type | 1 PDT |
|---|---|
| Type of switch contact | Single contact |
| Contact material | AgSnO |
| Maximum switching voltage | 250 V AC/DC |
| Minimum switching voltage | 5 V (at 100 mA) |
| Min. switching current | 10 mA (at 12 V) |
| Maximum inrush current | 10 A (4 s) |
| Limiting continuous current | 6 A |
| Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) |
| 20 W (at 48 V DC) | |
| 18 W (at 60 V DC) | |
| 23 W (at 110 V DC) | |
| 40 W (at 220 V DC) | |
| 1500 VA (for 250 V AC) | |
| Switching capacity | 2 A (at 24 V, DC13) |
| 0.2 A (at 110 V, DC13) | |
| 0.1 A (at 220 V, DC13) | |
| 3 A (at 24 V, AC15) | |
| 3 A (at 120 V, AC15) | |
| 3 A (at 230 V, AC15) | |
| Motor load according to UL 508 | 1/4 HP, 240 - 277 V AC (N/O contact) |
| 1/6 HP, 240 - 277 V AC (N/C contact) |
General
| Test voltage relay winding/relay contact | 4 kV AC (50 Hz, 1 min.) |
|---|---|
| Operating mode | 100% operating factor |
| Mechanical service life | 2x 107 cycles |
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
Connection data
| Connection method | Solder connection |
|---|
tandards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| EN 61810-1 | |
| Pollution degree | 3 |
| Overvoltage category | III |