Phoenix Signal conditioner - MINI MCR-SL-I-I-SP - 2864723
MCR 3-way signal conditioner, for electrical isolation of analog signals, with spring-cage connection, input signal: 0...20 mA /
4...20 mA, output signal: 0...20 mA / 4...20 mA. Replacement part: 2901999 MINI MCR-2-I-I-PT.
Key Commercial Data
| Orderkey | 2864723 |
|---|
| Packing unit | 1 pc |
|---|
| Catalog page | Page 97 (C-7-2015) |
|---|
| GTIN | 4017918974923 |
|---|
| Weight per Piece (excluding packing) | 63.800 g |
|---|
| Custom tariff number | 85437090 |
|---|
| Country of origin | DE (Germany) |
|---|
Dimensions
| Width | 6.2 mm |
|---|
| Height | 93.1 mm |
|---|
| Depth | 102.5 mm |
|---|
Ambient conditions
| Ambient temperature (operation) | -20 °C ... 65 °C |
|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
|---|
| Degree of protection | IP20 |
|---|
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
|---|
Input data
| Number of inputs | 1 |
|---|
| Configurable/programmable | no |
|---|
| Current input signal | 0 mA ... 20 mA |
|---|
| 4 mA ... 20 mA |
|---|
| Max. input current | 50 mA |
|---|
| Input resistance current input | approx. 50 Ω |
|---|
Output data
| Number of outputs | 1 |
|---|
| Configurable/programmable | no |
|---|
| Current output signal | 0 mA ... 20 mA |
|---|
| 4 mA ... 20 mA |
|---|
| Max. output current | 28 mA |
|---|
| Load/output load current output | < 500 Ω (at 20 mA) |
|---|
| Ripple | < 20 mVPP (at 500 Ω) |
|---|
Power supply
| Nominal supply voltage | 24 V DC |
|---|
| Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) |
|---|
| Max. current consumption | < 20 mA |
|---|
| Power consumption | < 450 mW |
|---|
Connection data
| Connection method | Spring-cage connection |
|---|
| Stripping length | 8 mm |
|---|
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
|---|
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
|---|
| Conductor cross section AWG | 24 ... 12 |
|---|
General
| No. of channels | 1 |
|---|
| Maximum transmission error | ≤ 0.1 % (of final value) |
|---|
| Maximum temperature coefficient | < 0.01 %/K |
|---|
| Temperature coefficient, typical | < 0.002 %/K |
|---|
| Limit frequency (3 dB) | approx. 100 Hz |
|---|
| Step response (10-90%) | approx. 3.2 ms |
|---|
| Protective circuit | Transient protection |
|---|
| Electrical isolation | Basic insulation according to EN 61010 |
|---|
| Overvoltage category | II |
|---|
| Degree of pollution | 2 |
|---|
| Rated insulation voltage | 50 V AC/DC |
|---|
| Test voltage, input/output/supply | 1.5 kV (50 Hz, 1 min.) |
|---|
| Electromagnetic compatibility | Conformance with EMC directive |
|---|
| Noise emission | EN 61000-6-4 |
|---|
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
|---|
| Color | green |
|---|
| Housing material | PBT |
|---|
| Mounting position | any |
|---|
| Assembly instructions | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
|---|
| Conformance | CE-compliant |
|---|
| ATEX | II 3 G Ex nA IIC T4 Gc X |
|---|
| UL, USA/Canada | UL 508 Recognized |
|---|
| Class I, Div. 2, Groups A, B, C, D T5 |
|---|
| GL | GL EMC 2 D |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
|---|
EMC data
| Designation | Electromagnetic RF field |
|---|
| Standards/regulations | EN 61000-4-3 |
|---|
| Typical deviation from the measuring range final value | 10 % |
|---|
| Designation | Fast transients (burst) |
|---|
| Standards/regulations | EN 61000-4-4 |
|---|
| Typical deviation from the measuring range final value | 10 % |
|---|
| Designation | Conducted interferences |
|---|
| Standards/regulations | EN 61000-4-6 |
|---|
| Typical deviation from the measuring range final value | 10 % |
|---|
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC directive |
|---|
| Noise emission | EN 61000-6-4 |
|---|
| Connection in acc. with standard | CUL |
|---|
| Designation | Electromagnetic RF field |
|---|
| Standards/regulations | EN 61000-4-3 |
|---|
| EN 61000-4-4 |
|---|
| Designation | Conducted interferences |
|---|
| Standards/regulations | EN 61000-4-6 |
|---|
| Electrical isolation | Basic insulation according to EN 61010 |
|---|
| Conformance | CE-compliant |
|---|
| ATEX | II 3 G Ex nA IIC T4 Gc X |
|---|
| UL, USA/Canada | UL 508 Recognized |
|---|
| Class I, Div. 2, Groups A, B, C, D T5 |
|---|
| GL | GL EMC 2 D |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 |
|---|
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
|---|